Cart(0)

You have no items in your cart

Last chance to save
Your Supplies...Delivered!
Call us at 307-423-0000

Key Features

  • VAuto auto-adjusting bilevel therapy – Automatically varies the pressure support gap between inhalation (IPAP) and exhalation (EPAP) to match your breathing throughout the night.
  • Expiratory Pressure Relief (EPR) – Reduces pressure during exhalation for a more natural, comfortable breathing feel.
  • HumidAir integrated humidifier – Built-in heated humidification reduces dryness and airway irritation without a separate device.
  • ClimateLineAir compatibility – Works with ResMed's heated tubing to prevent condensation and maintain consistent warmth and humidity.
  • TiControl – Lets clinicians set minimum and maximum inhalation time limits to prevent short cycling and reduce central apneas.
  • SmartStart/Stop + Mask Fit Check – Therapy starts and stops automatically; on-screen seal indicator confirms fit before sleep.
Description

The ResMed AirCurve 10 VAuto BiLevel BiPAP machine delivers auto-adjusting bilevel therapy — two separate pressure levels for inhalation and exhalation — making it a step up from standard CPAP for patients who find fixed or single-pressure therapy uncomfortable. This refurbished unit is a cost-effective way to access a clinically capable bilevel device with all consumable parts replaced new.

The VAuto algorithm continuously monitors your breathing and adjusts the pressure support gap between IPAP and EPAP throughout the night. Combined with EPR (Expiratory Pressure Relief), the machine eases back on pressure as you exhale, mimicking a more natural breathing feel. HumidAir integrated humidification and optional ClimateLineAir heated tubing maintain consistent moisture and temperature to reduce airway dryness across all sleep conditions.

SmartStart/Stop activates therapy automatically when you breathe into the mask and stops when you remove it — no buttons needed. The built-in mask fit check displays a simple on-screen indicator so you know before falling asleep whether your seal is effective.

Specifications
Specifications for Refurbished ResMed AirCurve 10 VAuto BiPAP Machine
Manufacturer ResMed
Model 37211, 37212, 37383
Warranty 1-Year Standard Warranty
HCPCS Codes E0470, E0562, A7037
Color Gray/Silver
Filters Disposable filter (1 included)
Operating Modes CPAP, S, VAuto
Altitude Adjustment Automatic up to 8500 ft
Sound Level 26.6 dBA
Carrying Case Yes, included
FAA-Approved Yes
Smartphone App ResMed myAir app
Machine Size Only 8" x 4.6" x 5.91" in
Machine Weight 2.45 lb
AC Input 100-240V, 50-60Hz
DC Converter Yes
Power Consumption N/A
Oxygen Purity Yes, ResMed AirSense/AirCurve 10 Oximetry Kit (370004)
Auto Start/Stop Yes
Machine Size with Humidifier 10" x 4.6" x 5.91" in
Humidification System Built-in heated humidifier
Integrated Heated Hose Included
Humidifier Settings 0-8
Water Chamber Capacity 380 mL
Power Cord Length 1.8 m (6 ft)
Battery Option Yes
Bluetooth No
Remote Monitoring Yes, built-in cellular modem
Data Download Yes via SD card
Pressure Range 4-20 cm H2O (CPAP); 2-25 cm H2O (S, VAuto)
Pressure Relief Easy-Breathe (VAuto, S), EPR 1 to 3 (CPAP only)
Starting Ramp Pressure 4 cm H2O default (CPAP only)
AHI Display Machine, App
Oxygen Use Yes, up to 4L/min
Oximetry Compatibility Yes, ResMed AirSense/AirCurve 10 Oximetry Kit (370004)
SD Card Included No
Operation Modes CPAP, S, VAuto
Leak Compensation Yes
AirView No
Built-in Cellular Technology Yes
Cell Type N/A
Effective Bluetooth Range N/A
Ramp Time Yes
Expected Service Life 5 years
HeatedYes
Reduces CondensationYes
Maintains Air TemperatureYes
Included items

Included with Machine:

  • AirCurve™ 10 VAuto 37211 Device (used)
  • ClimateLineAir Heated Tubing
  • AirSense/AirCurve 10 Water Chamber Standard
  • Humidifier
  • Power Cords
  • Travel Bag
  • User Manual

Additional Items Included:

  • SlimLine Tube

Note: This item is sold as an open box.

Related parts & accessories
Customer reviews (50)

Product questions & answers

What is the primary function of the ResMed 37212 AirCurve 10 VAuto Bi-Level Machine with HumidAir?
The ResMed 37212 AirCurve 10 VAuto Bi-Level Machine with HumidAir is designed to treat sleep apnea by providing two different pressure levels during inhalation and exhalation, along with integrated humidification to improve user comfort.
How does the integrated HumidAir humidifier function with the AirCurve 10 VAuto Bi-Level Machine?
The HumidAir humidifier is built into the device and can be adjusted to provide the desired level of humidity to the airflow, reducing dryness and irritation in the airways during therapy.
What are the benefits of using the AirCurve 10 VAuto Bi-Level Machine with HumidAir?
Some benefits of using the device with the HumidAir humidifier include improved comfort during therapy, reduced nasal congestion or dryness, and enhanced compliance with continuous positive airway pressure (CPAP) treatment.
How do I refill and clean the water chamber of the HumidAir humidifier?
The water chamber of the HumidAir humidifier should be emptied, cleaned, and refilled with distilled water before each use to maintain hygiene and prevent mineral buildup. Refer to the user manual for specific instructions.
Can I adjust the humidity level of the HumidAir humidifier?
Yes, you can adjust the humidity level of the HumidAir humidifier to suit your preferences. The level of humidity can be adjusted through the settings on the device itself.
Are there any special considerations when using the AirCurve 10 VAuto Bi-Level Machine with HumidAir?
It is important to use distilled water in the water chamber to prevent mineral deposits and ensure proper functioning of the humidifier. Regularly cleaning and replacing the water chamber components is also recommended.
Can I use the AirCurve 10 VAuto Bi-Level Machine without the HumidAir humidifier?
Yes, you can use the device without the HumidAir humidifier if preferred. Simply remove the humidifier chamber and close the lid before using the device.
How long does a ResMed AirSense 10 CPAP machine last?
Typically, CPAP machines like the ResMed AirSense 10 are recommended for use over three to five years. It's important to replace CPAP masks several times per year due to the wear and tear of components used regularly. Regular replacement ensures optimal performance and hygiene for an effective sleep apnea treatment plan.
How serious is being put on BiPAP?
Utilizing a BiPAP machine, like the ResMed AirCurve 10 VAuto Bi-level Machine, is generally safe, with lower risks of complications compared to more invasive ventilation methods. Most issues related to BiPAP therapy typically involve mask comfort and fit rather than serious medical concerns. Stay compliant with your prescribed therapy for optimal results.
Do I need a prescription to buy a Resmed AirCurve 10 VAuto Bi-level Machine?
Yes, a valid prescription from your healthcare provider is required to purchase the ResMed AirCurve 10 VAuto Bi-level Machine since it is classified as a medical device. Obtain the necessary documentation to access this advanced sleep apnea therapy solution.
Does Order Your Supplies provide an insurance receipt for this purchase?
Most products are sold as cash-pay purchases. After your order is placed, you can request an insurance-ready receipt with the item description, cost, and applicable HCPCS code. You can then submit it to your insurance provider to ask about out-of-network or self-purchase reimbursement if your plan allows it.

Need help with a different question? Contact our team or call 307-423-0000.

Compare with similar products

Compare the details below. On smaller screens, scroll the table sideways to see each product.

Product specifications for Refurbished ResMed AirCurve 10 VAuto BiPAP Machine and similar products
Specification Current item Refurbished ResMed AirCurve 10 VAuto BiPAP Machine From $779.00 ResMed AirCurve 10 VAuto BiPAP Machine with HumidAir From $1,209.00 Refurbished ResMed AirSense 10 CPAP with Humidifier From $549.00
Manufacturer ResMed ResMed ResMed
Model 37211, 37212, 37383 37211, 37212, 37383 37203, 37204
Warranty 1-Year Standard Warranty 2-Year Warranty 1-Year Standard Warranty
HCPCS Codes E0470, E0562, A7037 E0470, E0562, A7037 E0601
Color Gray/Silver Gray/Silver Black
Filters Disposable filter (1 included) Disposable filter (1 included) Disposable filter (1 included)
Operating Modes CPAP, S, VAuto CPAP, S, VAuto
Altitude Adjustment Automatic up to 8500 ft Automatic up to 8500 ft Automatic up to 8500 ft
Sound Level 26.6 dBA 26.6 dBA 26.6 dBA
Carrying Case Yes, included Yes, included Yes, included
FAA-Approved Yes Yes Yes
Smartphone App ResMed myAir app ResMed myAir app ResMed myAir app (iOS/Android)
Machine Size Only 8" x 4.6" x 5.91" in 8" x 4.6" x 5.91" in 8" x 4.6" x 5.91" in
Machine Weight 2.45 lb 2.45 lb 2.45 lb
AC Input 100-240V, 50-60Hz 100-240V, 50-60Hz 100-240V, 50-60Hz
DC Converter Yes Yes Yes
Power Consumption N/A N/A 53 Watts Typical; 104 Watts Peak
Oxygen Purity Yes, ResMed AirSense/AirCurve 10 Oximetry Kit (370004) Yes, ResMed AirSense/AirCurve 10 Oximetry Kit (370004)
Auto Start/Stop Yes Yes Yes
Machine Size with Humidifier 10" x 4.6" x 5.91" in 10" x 4.6" x 5.91" in 10" x 4.6" x 5.91" in
Humidification System Built-in heated humidifier Built-in heated humidifier Built-in heated humidifier
Integrated Heated Hose Included Included Included
Humidifier Settings 0-8 0-8 0-8
Water Chamber Capacity 380 mL 380 mL 380 ml to max fill line
Power Cord Length 1.8 m (6 ft) 1.8 m (6 ft) 1.8 m (6 ft)
Battery Option Yes Yes Yes
Bluetooth No No No
Remote Monitoring Yes, built-in cellular modem Yes, built-in cellular modem Yes, built-in cellular modem
Data Download Yes via SD card Yes via SD card Yes via SD card
Pressure Range 4-20 cm H2O (CPAP); 2-25 cm H2O (S, VAuto) 4-20 cm H2O (CPAP); 2-25 cm H2O (S, VAuto) 4-20 cm H2O
Pressure Relief Easy-Breathe (VAuto, S), EPR 1 to 3 (CPAP only) Easy-Breathe (VAuto, S), EPR 1 to 3 (CPAP only) EPR 1 to 3 (1 is min pressure relief, 3 is max)
Starting Ramp Pressure 4 cm H2O default (CPAP only) 4 cm H2O default (CPAP only) 4 cm H2O default
AHI Display Machine, App Machine, App Machine, app
Oxygen Use Yes, up to 4L/min Yes, up to 4L/min Yes, up to 4L/min
Oximetry Compatibility Yes, ResMed AirSense/AirCurve 10 Oximetry Kit (370004) Yes, ResMed AirSense/AirCurve 10 Oximetry Kit (370004) Yes, ResMed AirSense/AirCurve 10 Oximetry Kit (370004)
SD Card Included No No No
Operation Modes CPAP, S, VAuto CPAP, S, VAuto
Leak Compensation Yes Yes Yes
AirView No No
Built-in Cellular Technology Yes Yes Yes
Cell Type N/A N/A
Effective Bluetooth Range N/A N/A N/A
Ramp Time Yes Yes Yes
Expected Service Life 5 years 5 years 5 years
Heated Yes Yes
Reduces Condensation Yes Yes
Maintains Air Temperature Yes Yes

How may we assist you?

Our committed team is available to support you through every step of your treatment journey.